ID TECH Omni User Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 69
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
42
EXAMPLE TWO
*AST798X*
Symbology Code 39
Desired Output: The input record must be Code 39 and be exactly seven
characters in length with the seventh character being an “X”. It is divided into
three fields; the first three characters, the next three characters, and the last
character. The output should reverse the order of the first two fields, delete the
last character, and add an <ETX> (ASCII code 03) at the end of each field. In
addition, a time delay of 900 milliseconds should be added between the fields
(after the F1) and another delay of 2000 milliseconds added to the end of the
record.
Formula ID e LEN 07 07 M 07 X C 03 C 03 A \ 03
SEND BD DLY 09 AD DLY 20
Field List Field A AST
Field B 798
Field C X
Field D <ETX>
Keystroke Sequence
Enter Data Editing Setup /E/D/FJ<ENTER>
Enter Data Editing and Enable JA<ENTER>1<ENTER>
Enter Code ID and e (for Code 39) JC<ENTER>e<ENTER>
Enter Length and 0707 JD<ENTER>0<ENTER>7<ENTER>0
< ENTER >7<ENTER>
Enter Match and 07X JE<ENTER>0<ENTER>7<ENTER>
X<ENTER>
Enter Count and 03 JF<ENTER>0<ENTER>3<ENTER>
Enter Count and 03 JF<ENTER>0<ENTER>3<ENTER>
Enter Add Field & <ETX>
character JJ<ENTER>^C<ENTER> *
Enter Field Sequence and BD JK<ENTER>B<ENTER>D<ENTER>
Enter Add Delay and 09 JM<ENTER>0<ENTER>
9<ENTER>
Enter Field Sequence and AD JK<ENTER>A<ENTER>D<ENTER>
Enter Add Delay and 20 JM<ENTER>2<ENTER>
0<ENTER>
Enter Exit Setup JZ<ENTER>
Output Data 798<<ETX>>.9s delay AST<<ETX>>
2s delay
* ^C: Do a CTRL-C by holding down the <CTRL> key while pressing the C key, then
releasing both.
Page view 45