5. If UNMATCHED INPUT is set to SEND, the unmatched data is passed on
to the message processing section of the reader, where any previously-defined
postamble, preamble, and terminator characters are added before the data is
sent to the output port.
Examples
EXAMPLE ONE
76440057320712
Symbology Code 128
Desired Output: Divide the input data record into two fields with one consist-
ing of the first six digits and the second containing the remaining data. The
output should have a <CARRIAGE RETURN> or <CR> inserted after each
field.
Formula ID h C 06 A <ENTER> SEND ACBC
Field List Field A 764400
Field B 57320712
Field C <CR>
Keystroke Sequence
Enter Data Editing Setup /E/D/FJ<ENTER>
Enable Data Editing JA<ENTER>1<ENTER>
Enter Code ID as h (for Code 128) JC<ENTER>h<ENTER>
Define first six characters as Field A,
and remaining data as Field B JF<ENTER>0<ENTER>
6<ENTER>
Enter Add Field C as the <ENTER> key JJ<ENTER>^N<ENTER>*
Define Field Sending Sequence of ACBC JK<ENTER>A<ENTER>
C< ENTER>B<ENTER>
C<ENTER>
Save Exit Setup JZ<ENTER>
Output Data 764400<CR>
57320712<CR>
* ^N: Do a CTRL-N by holding down the <CTRL> key while pressing the N key, then
releasing both.
Page view 44