Codabar Settings:
Enable/Disable Codabar
If enabled, Codabar symbology will be read, subject to the reading restric-
tions specifi ed by this set of options. If disabled, the data from the symbology
will be disregarded.
SELECTION CODE: F5
Codabar Enable A
Codabar Disable B
Send Start/Stop Characters
Codabar uses the A, B, C, and D characters as Start and Stop characters, giv-
ing 16 unique Start/Stop character combinations. Some applications require
that these characters be transmitted with the data while others specify that
they must not be sent.
SELECTION CODE: F5
Send Start/Stop C
Do Not Send Start/Stop D
Check Digit
When Check Digit is selected, the reader takes the last character in the de-
coded data stream as a check digit. It then calculates the correct check digit
for the remaining data and compares it to the last data character. If it is the
same, the data is accepted. If not, the data is rejected. With the Calculate and
Send Check Digit option, the reader will send the check digit as part of the
data stream. If the Calculate but Do Not Send Check Digit option is selected,
the reader will strip it from the data stream before transmission. If the Check
Digit is not calculated, the reader will assume the last data character read
from the symbol is part of the data stream and will not make a comparison
test.
SELECTION CODE: F5
Do Not Calculate Check Digit but Send Whole Data Stream E
Calculate and Send Check Digit F
Calculate but Do Not Send Check Digit G
SELECTION CODE: F5
Codabar Enable A
Codabar Disable B
Codabar Enable A
Codabar Disable B
SELECTION CODE: F5
Send Start/Stop C
Do Not Send Start/Stop D
Send Start/Stop C
Do Not Send Start/Stop D
Do Not Calculate Check Digit but Send Whole Data Stream E
Calculate and Send Check Digit F
Calculate but Do Not Send Check Digit G
SELECTION CODE: F5
Do Not Calculate Check Digit but Send Whole Data Stream E
Calculate and Send Check Digit F
Calculate but Do Not Send Check Digit G