EXAMPLE THREE
%B0123774965^FISH/MARY^96124379F?
MSR Track 1 data
Desired Output: Divide it up into seven fi elds so that the 1st fi eld is the fi rst
two characters, 2nd fi eld is all characters from the fi rst fi eld to the fi rst “^”
character, 3rd fi eld is the fi rst “^” character, 4th fi eld is the data between “^”
marks, 5th fi eld is the next “^” character, 6th fi eld is the next four characters,
7th fi eld is the remaining characters. In addition, an <ENTER> is inserted
between fi elds in the data output record. Only the 4th, 2nd, and 6th fi elds are
outputted.
Formula ID k C 02 S ^ S ^ C04 A<ENTER> SEND
DHBHFH
Field List Field A %B
Field B 0123774965
Field C ^
Field D FISH/MARY
Field E ^
Field F 9612
Field G 4379F?
Field H <ENTER>
Prior to data editing, enable the Function Code Selection on page 9.
Keystroke Sequence
Enter Data Editing Setup /E/D/FJ<ENTER>
Enter Data Editing and Enable JA<ENTER>1<ENTER>
Enter Code ID and k (for MSR Track 1) JC<ENTER>k<ENTER>
Enter Count and 02 JF<ENTER>0<ENTER>
2<ENTER>
Enter Search String and the ^ character JG<ENTER>^<ENTER>
Enter Search String and the ^ character JG<ENTER>^<ENTER>
Enter Count and 04 JF<ENTER>0<ENTER>
4<ENTER>
Enter Add Field & the <ENTER> character JJ<ENTER>\<ENTER>
Enter Field Sequence and DHBHFH JK<ENTER>D<ENTER>
H<ENTER>B<ENTER>
H<ENTER>F<ENTER>
H<ENTER>
Enter Exit Setup JZ<ENTER>
Output Data FISH/MARY<ENTER>
0123774965<ENTER>
9612<ENTER>
Page view 47